Electric

Top Performer Plus
Top Mount Coil

Model TPP
Top Performer Plus
 

Commercial
Indirect

Model CI
Hotstow
 

Indirect Water Heater
Thermoplastic Storage Tanks

Model PF
Model PF
 
Top Performer Plus

Commercial

Model S
Commercial
 

Residential

Model ME
Residential
 

Hybrid Heat Pump

Model WHPT
Hybrid Heat Pump Water Heater
 

Grid Enabled Storage

Model ME
Grid Enabled Electic Water Heater
 

Commercial Light Duty

Model LDC
Commercial Light Duty
 

Commercial Heavy Duty

Model A4
Commercial Heavy Duty
 

Sanitizer

Model SD
Sanitizer
 
Placeholder

Condensing Gas

Model GC
Condensing Gas
 

Non Condensing Gas

Model GN
Condensing Gas
 
Placeholder

Solar

Model SRW
Solar Water Heater
 
Placeholder

Buffer Tanks

Model D4B
Buffer Tanks
 

Aqua Booster

Model CW
Aquabooster
 

Geothermal

Model D4
Geothermal
 

Range Boilers

Model RB
Range Boiler
 

Timers / Energy Controllers

Energy Controllers
 

Temperature
Controllers

Temperature Controllers
 

Grid Interactive Controllers

Grid Interactive Controls
 

Custom Controllers

Custom Controllers
 

Custom Designed

 
Placeholder
Indirect
Storage
Solar
Controls
Gas
Custom
Product Center
Standard Blue Product Header
Gas Water Heater
Non Condensing Series
Model GN  (Atmospheric Burner)
Bookmark and Share
Still have questions? Complete this form
*Name:
*Email:
*State /
Province:
*Comment:

High Performance and High Efficiency

Non Condensing gas storage tank water heater with cement lining and fully integrated burner and heat exchanger. Sizes 40 thru 120 gallon and up to 55k BTU.

Consult Factory for More Information on This Product.
Condensing Gas Water Heater

  • Easy installation
  • Increased Capacity
  • Allows for High flows
  • Dump loads
  • 200,000 to 250,000 BTUs
  • 40 to 120 Gallon
  • Hydrastone Cement Lined Tank
  • 10 year tank warranty

Coming Soon

This products specifications are coming soon.

Coming Soon

Model Numbers for this product is coming soon.

Non Condensing Gas Series Specific Questions

Why is dielectric isolation so important?

The unique design of the Vaughn heat exchanger electrically isolates the heat exchanger from the tank by means of a non conductive barrier installed between the two. This provides dielectric isolation between the tank and the heat exchanger thereby eliminating electrolysis between the two due to dissimilar metals. This feature is one reason why the Vaughn indirect water heater far outlasts competitor models.

What is a sacrificial anode and does a cement lined tank need one?

All water heaters constructed using a steel tank requires a lining to protect the internal steel surfaces from corrosion. Certain linings (i.e. glass and epoxy), due to their nature, have unavoidable holes and imperfections resulting in exposure of the steel tank. As a result of this deficiency, the manufacturer will install an anode rod(s) in an attempt to delay corrosion of the steel tank. An anode rod is typically made of aluminum, magnesium or zinc, is a maintenance item that requires periodic inspection and replacement, and is often times the cause of a “rotten egg” odor to your hot water. Often referred to as a sacrificial anode rod because, over time, it slowly dissolves, sacrificing itself as it is attacked by aggressive substances in the water which would otherwise attack the steel tank through the pinholes and imperfections of the glass or epoxy lining. A cement lined steel tank on the other hand does not require an anode because of the thickness and guaranteed 100% coverage of the cement lining over all internal surfaces of the steel tank. This eliminates the need for an anode rod in a cement lined water heater, resulting in a significantly longer life compared to a glass or epoxy lined water heater. For a further discussion please click on the following link Cement Lining

Do I need a drain pan under my heater?

Yes, Vaughn advises that a drip pan with a proper drainage connection be installed under your water heater. In some locations drip pans are required by code and in other situations they are highly recommended, but not required. In either case, if a water heater leak or a dripping relief valve could result in property damage then a drip pan must be installed under the water heater, even when not required by code.

General Questions

Are Vaughn heaters made in the USA?

Yes. Vaughn water heaters are all made in the USA and our factories located in Connecticut and Massachusetts and qualify for incentives under The Buy American Act and the American Recovery and Reinvestment Act (ARRA). For more information go to the following link Here.

Where can I purchase a Vaughn water heater?

There are numerous ways to purchase a Vaughn water heater depending upon the model you desire and your geographic location. The easiest way is either to visit our "Where to Buy" option in the red menu bar across the website, or contact Vaughn directly at 978-462-6683 and ask for the sales department where you will be directed to either our local representative or our order entry department for quick and easy ordering.

What code requirements are applicable for my installation?

The installation of water heaters are mostly governed by the Uniform Plumbing Code (or CPC in California), Uniform Mechanical Code, and National Electrical Code. These are standard codes that are used across the United States, and each state can amend them as they wish. To take it further, each city and county jurisdiction has assigned one or more building officials with what is called Administrative Authority. This Authority" allows each jurisdiction the right to interpret the codes as they see fit. Because of this many cities differ on their requirements. Vaughn strongly recommends that you contract with a plumbing engineer who knows and understands the intricacies of the building code requirements for your location.

Is it OK if my plumbing system has plastic pipes (PVC or PEX)?

Yes. All Vaughn water heaters will work with both types of plastic piping.

My question is not found in these FAQ’s, where do I look next?

Check out the Vaughn Product Center at Here for a complete listing of all technical Operation & Maintenance manuals documentation available by model. Get easy access to Installation Sales Brochures Service Bulletins Wiring Schematics Parts Breakdowns and various other technical documents related to the full line of Vaughn water heaters. Or if you prefer please call us at 978-462-6683 and ask to speak with Sales.

Downloads

Technical Documents

  • Non Condensing Gas Series Brochure PDF (- MB)

Many of our products literature is available online for download. To open these files, a PDF viewer is required. If you do not have one, Adobe provides Acrobat Reader free of charge for viewing only. Use this link to download Acrobat Reader. You may also choose to download the file to your PC for future reference or printing. On most operating systems, simply right-click on the links below, choose "Save target as..." or "Save link as...", choose a location and it will save the document to your computer for future reference.


Vaughn Water Heaters Logo
26 Old Elm Street
P.O. Box 5431
Salisbury, MA 01952-5431
Tel: 978-462-6683
Fax: 978-462-6497

Partner Center

Coming Soon
  • Contractors
  • Wholesaler/Dealer
  • Utilities

Product Center

Vaughn Catalog
View our current digital materials available in our product center.

To Product CenterYellow arrow

News Icon Latest News