Your browser is out of date.

You are currently using Internet Explorer 7/8/9, which is not supported by our site. For the best experience, please use one of the latest browsers.

High Efficiency and Durability

Commercial Stonelined Range Boiler

30-119 Gallon
Efficient
Long Lasting
Superior Performance

The Vaughn range boiler combines a HydraStone lining and heavy gauge steel for an effective, long-lasting, and reliable range boiler. The tank can provide a large volume of hot water, depending on tank size, by using a separate hot water tank that is connected to a heating boiler as well as to domestic hot water piping in a home. Water circulates from inside the range boiler tank through a heat-exchange coil that may be internal or external to the heating boiler. This is the perfect tank to use in conjunction with your wood cook stove or heater.

Request A Quote

Features

  • HydraStone Lining - A seamless one-half inch thick lining that has proven to be the most effective method of preventing tank failure due to corrosion
  • Bronze Fittings - At all six tappings eliminates corrosion due to dissimilar metals. No dielectric unions or anode rod are required.
  • Hand Hole Cleanout Option - Allows for easy inspection and cleaning of the bottom of tank
  • Wide Selection - Models in 30, 40, 80, and 119 gallons
  • Protected in Shipping - Container allows for easy inspection and disposal
  • Warranty - 5 year limited tank 

Additional Product Details

range dimensions

Specifications

Model Capacity Height Diameter A B C Tapping Size Weight
T30-RB 30 Gal 39.5 16 23 30.75 11 1 NPT 180
T40-RB 40 Gal 56.75 16 33 45.625 11 1 NPT 212
T80-RB 80 Gal 56 22 33 46 11 1 NPT 280
T120-RB 119 Gal 67 24 33 57 11 1.5 NPT 395
  • All tappings 1" excluding 120 Gal. model has 1 1/2" fittings
  • Hand hole cleanout option
  • Temperature and pressure relief valve required
range dimensions
  • 4" hand hole cleanout

Range Boiler Specific Questions

All water heaters constructed using a steel tank requires a lining to protect the internal steel surfaces from corrosion.  Certain linings (i.e. glass and epoxy), due to their nature, have unavoidable holes and imperfections resulting in exposure of the steel tank.   As a result of this deficiency, the manufacturer will install an anode rod(s) in an attempt to delay corrosion of the steel tank.  An anode rod is typically made of aluminum, magnesium or zinc, is a maintenance item that requires periodic inspection and replacement, and is often times the cause of a “rotten egg” odor to your hot water.  Often referred to as a sacrificial anode rod because, over time, it slowly dissolves, sacrificing itself as it is attacked by aggressive substances in the water which would otherwise attack the steel tank through the pinholes and imperfections of the glass or epoxy lining.  A cement lined steel tank on the other hand does not require an anode because of the thickness and guaranteed 100% coverage of the cement lining over all internal surfaces of the steel tank.  This eliminates the need for an anode rod in a cement lined water heater, resulting in a significantly longer life compared to a glass or epoxy lined water heater.
It depends.  The Uniform Plumbing Code (UPC), section 510.5 states In seismic zones 3 and 4 water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third (1/3) and lower one-third (1/3) of its vertical dimensions. At the lower point a minimum of four (4) inches (102mm) shall be maintained above the controls with the strapping."  If the installed location is in these seismic zones then a strap/restraint system is required.  Otherwise please consult with a plumbing engineer to determine the proper installation method for your water heater.
Yes, Vaughn advises that a drip pan with a proper drainage connection be installed under your water heater.   In some locations drip pans are required by code and in other situations they are highly recommended, but not required.  In either case, if a water heater leak or a dripping relief valve could result in property damage then a drip pan must be installed under the water heater, even when not required by code.
The water heater must be stored in the orientation of intended use (vertical, horizontal). The recommended ambient air temperature range is between 50 and 105 degree F and not exceeding 65% Rh. Under no conditions should the unit be subject to freezing temperatures. The unit is intended to be stored indoors, protected from the elements. Desiccant material should be inserted into the electric control panel and heating element terminal house (if applicable). Prolonged storage will require periodic inspection of desiccant. For cement lined tanks only, place approximately 10 gallons of water in the tank before closing and sealing all openings to ensure a humid atmosphere for the lining is maintained. Cap and seal all openings and tank tappings and/or flanges. Provide the necessary protection to ensure the tank and all accessories are protected from physical contact that could result in damage. Shrink wrapping or other suitable protective plastic may be applied to the exterior. Start up and installation guidelines must be followed, with particular attention to testing of the electric heating element.
The HydraStone lining provides guaranteed 100% coverage with a minimum thickness of 0.5” over all internal tank surfaces. In comparison, glass lining is approximately 0.005” thick and includes imperfections, pinholes and variation in coverage thickness resulting in portions of unprotected steel tank exposed to corrosion. In an attempt to compensate, glass lined tanks include a sacrificial anode in an effort to slow down the corrosion of the tank. HydraStone lined tanks on the other hand do not require an anode due to the integrity of the lining. As such, a cement lined tank will far outlast a glass lined tank.
Although we don’t advocate dropping our tanks, sometimes stuff happens. The Vaughn HydraStone lining is a minimum of 1/2" thick (100 times thicker than a glass lined tank) and is guaranteed to uniformly cover 100% of all internal tank surfaces. In essence, the Vaughn HydraStone lining is a tank within a tank and should have no problem withstanding the rigors of shipping and installation. A properly maintained Vaughn tank will last decades.
Legionella is the bacteria responsible for Legionnaire’s Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria.   Legionella is a fairly common water bacterium and has been found to exist widely in many surface water sources including lakes, rivers, streams and ponds.  It can also be found in ground water sources and some soils.   At the levels found in these naturally occurring sources it typically does not pose a threat to public health.  When the bacterium enters a domestic water system it can find an ideal host environment of warm water temperatures (105-115°F), stagnant water areas (isolated storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaire’s Disease.    There are many methods of controlling colonization of Legionella bacteria; a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 140°F.  Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries.  As such, many plumbing engineers will specify that the water heater be set to maintain water temperatures at 140°F or higher to reduce the risk of Legionella, but then specify the appropriate mixing valve to ensure safe delivery of hot water to the fixtures.  For a more thorough discussion of Legionella please go to here and the following link to the US Department of Labor OSHA information regarding Legionnaires’ Disease OSHA here
The unique design of the Vaughn heat exchanger electrically isolates the heat exchanger from the tank by means of a non conductive barrier installed between the two. This provides dielectric isolation between the tank and the heat exchanger thereby eliminating electrolysis between the two due to dissimilar metals. This feature is one reason why the Vaughn indirect water heater far outlasts competitor models.